EMC Symmetrix Solutions Expert Exam for Technology Architects - E20-816무료 덤프문제 풀어보기
Refer to the exhibit.

A customer has a Symmetrix VMAX storage array which had a capacity add completed after one year of service. Performance for a specific host application with large block I/O has not achieved expected levels of performance. The customer requests a performance review and determination of the problem.
You determine that FA processors are running 52% busy, FA ports have an average of 30 MB/s and disks in the thin storage pool are 28% utilized. Which cost effective solution should be suggested?

A customer has a Symmetrix VMAX storage array which had a capacity add completed after one year of service. Performance for a specific host application with large block I/O has not achieved expected levels of performance. The customer requests a performance review and determination of the problem.
You determine that FA processors are running 52% busy, FA ports have an average of 30 MB/s and disks in the thin storage pool are 28% utilized. Which cost effective solution should be suggested?
정답: B
Refer to the exhibit.

An SRDF/Star configuration has production running at Site A.
A symstar halt command is executed at the workload site (Site A). Which action would reconfigure the RDF device relationships such that the workload site is located at Site B and both RDF targets are in the disconnected state?

An SRDF/Star configuration has production running at Site A.
A symstar halt command is executed at the workload site (Site A). Which action would reconfigure the RDF device relationships such that the workload site is located at Site B and both RDF targets are in the disconnected state?
정답: A
What are examples of metrics collected at the LUN and sub-LUN level by FAST VP during user defined performance windows?
정답: B
You are architecting a VMware virtualized Exchange 2010 solution that will include replication of the Exchange volumes using VMware snapshots. Which type of storage should be presented to the VMs in order to facilitate replication?
정답: B
You are designing a boot from SAN solution for VMware ESXi servers connected to a Symmetrix VMAX storage array. What is a consideration?
정답: A
What are the EMC recommended symacl permissions that should be assigned for the Symmetrix Service Processor?
정답: C
A VMware customer noticed slow performance of virtual machines hosted on an ESXi host. Which value indicates that the ESXi host is overloaded and is causing virtual machine slow performance?
정답: A
A customer is planning a new Exchange 2010 environment on their EMC VMAX. The customer asks how they can backup volumes containing active mailbox databases. What do you advise the customer?
정답: C
Click on the calculator icon in the upper left corner.
A customer is implementing an Exchange environment on an EMC Symmetrix VMAX. The environment will be deployed on 600 GB FC 15K drives using RAID 1 data protection. The application generates 1350 I/O per second and has a 2:1 read/write ratio.
What is the minimum number of drives recommended to support the application?
A customer is implementing an Exchange environment on an EMC Symmetrix VMAX. The environment will be deployed on 600 GB FC 15K drives using RAID 1 data protection. The application generates 1350 I/O per second and has a 2:1 read/write ratio.
What is the minimum number of drives recommended to support the application?
정답: A