Huawei Certified Field Specialist -Smart PV Controller - H20-681-ENU무료 덤프문제 풀어보기

Which of the following about the description of Huawei SmartLogger accessing third-party devices is correct? (Multiple Choice)

정답: A,B,C
When the Huawei SUN2000 inverter is alarmed and cannot be connected to the network, the alarm ID is 301-31. Which of the following measures can be taken to troubleshoot or try to solve?

정답: B
Regarding the input current detection circuit of Huawei SUN2000 inverter, which of the following statement is correct?

정답: A
The rated output current of Huawei PID module is ____.

정답: D
Regarding the shutdown operation of Huawei SUN2000 inverter, which of the following description is correct? (Multiple choice)

정답: B,C,D
The project manager must manage the production safety, and the safety management must adhere to the principle of "safety first, prevention first". The project PM is the first responsible person for safety production.

정답: A
When Huawei SmartLogger "Device Auto Access" is set to "Enable", SmartLogger will automatically search for devices every 10 minutes and automatically access new devices.

정답: A
During the upgrade of the SUN2000 inverter software, disconnecting the DC input switch of the inverter may cause the inverter to fail to upgrade. When the inverter DC switch is closed again, the "software version mismatch" alarm may occur and the grid cannot be generated. Need to be re-upgraded to resolve.

정답: A
The Huawei SUN2000 inverter has an alarm with an alarm ID of 200-12 (DC circuit abnormality). The cause of the alarm is BOOSTA input current hardware overcurrent.

정답: A
When the debugging of the Huawei PLC communication network is started, which of the operation description of setting the anti-crosstalk is correct? (Multiple Choice)

정답: A,B,C,D
Low Voltage Ride Through (LVRT) means that when a power system accident or disturbance causes a voltage drop at the grid connection point of a PV power plant, the PV power plant can ensure continuous operation without off-grid.

정답: B
When the Huawei SUN2000L household inverter is powered on, first close the external power distribution AC switch, then close the DC switch on the inverter, and finally close the external DC switch.

정답: B
Before logging in to the NetEco1000S system, you need to enable the NetEco1000S service. Otherwise, users cannot log in to the NetEco1000S system.

정답: A
The SmartLogger200 has a built-in Bluetooth module, which can be connected to the SmartLogger via Bluetooth for parameter setting and maintenance.

정답: A