Network Appliance NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP - NS0-506무료 덤프문제 풀어보기

Click the Exhibit button.
cl01::>iscsi portal show
Logical Status CurrCurr
Vserver Interface TPGT
Admin/Oper IP Address Node
Port Enabled
---------- ---------- ---- --
-------- ---------------- ----
------- ---- -------
svm1 1-a 1035 up/up
192.168.1.66 cl01-01 e0a true
svm1 1-b 1051 up/up
192.168.1.67 cl01-01 e0b true
svm1 2-a 1046 up/down
192.168.1.68 cl01-02 e0a true
svm1 2-b 1052 up/up
192.168.1.69 cl01-02 e0b true
Referring to the exhibit, which action would you take to troubleshoot the iscsi-2-a interface?

정답: C
A customer has recently deployed a clustered Data ONTAP 8.3 system and is trying to mount LUNs to a Windows 2012
Server using the iSCSI protocol. They are using Cisco Nexus 5548 network switches and the network administrator has
informed the storage administrator that the ports are set to switchport mode trunk. The storage administrator has
also been informed that the host and storage should be using VLAN 400 for iSCSI traffic. When the storage
administrator attempts to add the SVM as an iSCSI target, it fails to connect.
What is causing the problem?

정답: C
Click the Exhibit button.
cl01::>lun resize -vserver
svm1 -volume db1_vol -lun db1
-size 4096g
Error: command failed: New
size exceeds this LUN's
initial geometry
cl01::>
What is the reason for the error shown in the exhibit?

정답: B
설명: (Fast2test 회원만 볼 수 있음)
Click the Exhibit button.

A customer has deployed a new FAS8080EX running clustered Data ONTAP 8.3. Host A is running multipath software
that has been properly configured. Also, Host A is currently accessing a LUN using the FC protocol stored on Node

정답: E
A new server has been installed in your environment, but it is unable to see its NetApp boot LUN. You have narrowed
the problem down to the zoning on your Cisco switch which has the following configuration:
zone name z_NetAppvsan 400
memberpwwn 20:00:00:25:b5:c0:ff:ee
memberpwwn 50:0a:09:84:8d:7c:51:d5
zoneset name zs_NetAppvsan 400
memberz_NetApp
zoneset activate name zs_NetAppvsan 400
What is the problem with your zoning configuration?

정답: D
Click the Exhibit button.
cl01::>ucadmin show
Current Current Pending
Pending Admin
Node Adapter Mode Type Mode
------------- ------- -------
--------- -------- --------- -
----------
cl01-01 0c fc target - -
online
cl01-01 0d fc target - -
online
cl01-01 3a cna target - -
online
cl01-01 3b cna target - -
online
cl01-01 4a cna target - -
online
cl01-01 4b cna target - -
online
cl02-01 0c fc target - -
online
cl02-01 0d fc target - -
online
cl01-02 3a cna target - -
online
cl01-02 3b cna target - -
online
cl01-02 4a cna target - -
online
cl01-02 4b cna target - -
online
12 entries were displayed.
cl01::>
Referring to the exhibit, which cables are valid for connecting port 0d on node cl01-02 when the switch is 10 meters
away?

정답: C
What does Selective LUN Mapping (SLM) do?

정답: B
설명: (Fast2test 회원만 볼 수 있음)
A company has a 4-node Data ONTAP cluster called cl01. The administrator attempts to create a volume on svm1 and
can only select aggregates that are owned by node cl01-01 or cl01-02.
What is causing the problem?

정답: D

우리와 연락하기

문의할 점이 있으시면 메일을 보내오세요. 12시간이내에 답장드리도록 하고 있습니다.

근무시간: ( UTC+9 ) 9:00-24:00
월요일~토요일

서포트: 바로 연락하기 

English Deutsch 繁体中文 日本語