IBM Power Systems with POWER7 Common Technical Sales Skills -v2 - 000-224무료 덤프문제 풀어보기
A customer has a Power Systems server with storage attached in two EXP24 expansion units. Each EXP24 is populated with 10 disks and is attached to its own SAS RAID adapter. The usable storage is approximately 80% full across the 20 units and currently uses RAID-5 for disk protection.
The customer is concerned about the time required between a drive failure and when disk protection is restored. Which of the following should the customer consider to minimize the recovery time and minimize additional hardware costs?
The customer is concerned about the time required between a drive failure and when disk protection is restored. Which of the following should the customer consider to minimize the recovery time and minimize additional hardware costs?
정답: C
Which of the following is a benefit of Intelligent Cache management in the POWER7+ chip?
정답: D
A customer with POWER 7 + 780 servers would like to contain processor related charges with Capacity on Demand for workloads which run in dedicated and shared LPARs and have pronounced seasonal peaks.
What type of Capacity on Demand (CoD) should be considered?
What type of Capacity on Demand (CoD) should be considered?
정답: A
A customer is managing a Power 720 with dual VIO Servers with a 7310-CR4 HMC. A PS701 blade which requires Active Memory Expansion (AME) will be added to the environment. Existing resources must be reused as much as possible.
Which of the following supports the configuration?
Which of the following supports the configuration?
정답: B
Active Memory Sharing (AMS) for an HMC managed system with multiple partitions is being planned.
In addition to updating system firmware, HMC, and modifying partition definitions, which of the following must be considered?
In addition to updating system firmware, HMC, and modifying partition definitions, which of the following must be considered?
정답: A
What feature of the POWER7 processor design allows the system to recover from soft or transient errors in the processor core?
정답: B
Which of the following PowerVM Editions is required to take advantage of Live Partition Mobility?
정답: C
A customer has a 6-core Power 720 installed in a rack. The Power 720 has all internal disk bays populated.
The customer is considering adding Solid State Drives (SSDs) in a 12X I/O drawer.
Assuming the I/O drawer will fit in available rack space, what else must be considered?
The customer is considering adding Solid State Drives (SSDs) in a 12X I/O drawer.
Assuming the I/O drawer will fit in available rack space, what else must be considered?
정답: C
A customer needs to perform a disruptive server firmware upgrade, and plans to move partitions to another server. What benefit of virtualization is being utilized?
정답: A